6.1.2 Incorrect Axis Direction
Cause
1. Incorrect polarity of port Reference Point.
2. Incorrect value of parameter Axis Direction.
Solution
1. Convert its polarity. See Execute I/O Port Related Operations for details.
2. Change its value to the opposite value. See Adjust the Axis Direction for details.
6.1.3 Coarse Positioning Speed is Too Slow
Cause
1. Too small value of parameter Coarse Positioning Speed.
2. Polarity of port Reference Point does not match with type of the origin switch.
Solution:
1. Modify its value to a larger value.
2. Convert its polarity. See Execute I/O Port Related Operations for details.
6.2 Questions about Warnings
It includes the following common warnings:
• Simulation result shows running range exceeded machine stroke. Switch to log
window to learn more
• Cannot execute the operation. The system has not returned to the machine
origin
• The parser is busy. Cannot execute the operation
6.2.1 Simulation Result Shows Running Range Exceeded Machine Stroke.
Switch to Log Window to Learn More
Cause
The workbench stroke in the toolpath file exceeds the set upper limit and lower
limit of workbench stroke.
Solution
1. Check the workpiece origin:
– If it is set reasonably, proceed to next step.
– If it is not set reasonably, set it again. See Set the Workpiece Origin for
details.