上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
35 / 36
2. Check the workbench stroke in the toolpath file:
– If it is reasonable, modify parameters Workbench Stroke Upper Limit
and *Workbench Stroke Lower Limit to enlarge the workbench stroke.
– If it is not reasonable, modify the workbench stroke in the toolpath file.
6.2.2 Cannot Execute the Operation. The System has not Returned to
the Machine Origin
Cause
The system has not returned to the machine origin.
Solution
Return to the machine origin first. See Confirm Machine Coordinates of Double Tools
for details.
6.2.3 The Parser is Busy. Cannot Execute the Operation
Cause
Cannot execute the operation in running status.
Solution
Execute the operation in idle status by stopping machining or waiting for the end of
the machining.
6.3 Questions about Alarms
It includes the following common alarms:
• Limit alarm
• Servo alarm
• E-stop alarm
• Alarm of terminal board disconnection
6.3.1 Limit Alarm
Cause
1. Incorrect polarity of port Negative Limit / Positive Limit.
2. Axis collided with the limit switch.
3. Limit switch failure.
Solution
1. Convert its polarity. See Execute I/O Port Related Operations for details.
2. Manually move the axis away from the limit switch.