2 Commissioning
This section mainly introduces operations to quickly do commissioning for Double-
tool CNC System.
The process for commissioning is as follows:
1. Clear I/O port alarms
2. Set drive parameters
3. Clear drive alarms
4. Set commissioning parameters
5. Adjust the axis direction
6. Confirm machine coordinates of double tools
7. Execute analog machining
If there is no special instruction, the above operations are executed in Technician
interface, and manufacturer permission is required.
2.1 Clear I/O Port Alarms
This operation is used to clear I/O port alarm so as to establish good communication
between the system and the servo drive.
Common I/O port alarms are as follows:
Clear the E-stop alarm
Clear the limit alarm
Clear the drive alarm
To modify port polarity, see Execute I/O Port Related Operations for details.
2.1.1 Clear the E-stop Alarm
To clear the E-stop alarm, check if E-stop button is pressed:
If it is, release the button.
If it is not, modify the polarity of port E-stop.
2.1.2 Clear the Limit Alarm
When the machine tool triggers the limit switch, the system will send a
positive/negative limit alarm.
To clear the limit alarm, move the machine tool towards the opposite direction of
the limit switch.