EasyManuals Logo

WEIHONG NC65C User Manual

Default Icon
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
36 / 36
3. Replace the limit switch.
6.3.2 Servo Alarm
Cause
1. Incorrect polarity of port Servo Alarm.
2. Alarm in servo drive.
Solution
1. Convert its polarity. See Execute I/O Port Related Operations for details.
2. Check servo connecting wire.
6.3.3 E-stop Alarm
Cause
1. The E-stop button is pressed.
2. Incorrect polarity of port Emergency Stop.
3. Alarm in inverter.
Solution
1. Rotate the button clockwise.
2. Convert its polarity. See Execute I/O Port Related Operations for details.
3. Troubleshoot according to alarm type of the inverter.
6.3.4 Alarm of Terminal Board Disconnection
Cause
1. Incorrect polarity of port Terminal Board Disconnection / Extended
Terminal Board 1 Disconnection / Extended Terminal Board 2
Disconnection.
2. The cable has not been firmly connected.
3. Terminal board failure.
Solution
1. Convert its polarity. See Execute I/O Port Related Operations for details.
2. Re-plug the cable, and restart the software.
3. Check indicator lights on terminal board:
If they are on, contact your supplier.
If they are off, replace the terminal board.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEIHONG NC65C and is the answer not in the manual?

WEIHONG NC65C Specifications

General IconGeneral
BrandWEIHONG
ModelNC65C
CategoryControl Systems
LanguageEnglish

Related product manuals