1
WEILER E1650 REMIXING TRANSFER VEHICLE
5-14
Maintenance
5
Maintenance Procedures
Chain tension diagnostics are displayed on the “View
Elevator/Storage Diagnostics” screen. Data includes auto
tension valve state (on/off) and the number of successful
automatic cycles (override cycles are not included).
Manually Starting an Auto-Adjust Cycle
An auto-adjust cycle can be started by the operator to
tension the discharge conveyor chain.
1. Start engine and run 2–3 minutes.
2. Run discharge conveyor for 2–3 minutes. Hydraulic
pressure must be <1500 psi (103.4 bar).
NOTICE: Do not start auto-adjust cycle while machine is
moving material.
3. On electronic display, select Menu Screen.
4. Select System Settings.
5. Select System Parameter Settings.
6. Select Chain Tension Override.
Auto-adjust cycle will tension the discharge conveyor
chain.
View Elevator/Storage Diagnostics
Exit Page 2 of 2
Auto Tension Cycles
Auto Tension
Warm-Up
Elevator Switch
Storage/Discharge Switch
10
Off
Not Complete
Off
Off
Menu Screen
View Engine Diagnostics
View Drive Diagnostics
View Elevator/Remix Diagnostics
View Sensor Diagnostics
View CAN Diagnostics
System Settings
View Errors
Exit Enter
System Parameter Settings
Exit
Remix Stall Pressure
Elevator Delay
Reset All
Tire Wash Override
Distance Control Enable
Tire Spray Enable
Parameter Name
0
0
0
0
0
0
0
0
Value
Chain Spray Enable
Chain Spray time
Chain Tension Override
0
Spray Pump Time 0
Page
Up
Page
Down
Select

Related product manuals