WEILER E1650 REMIXING TRANSFER VEHICLE
A-5
Hydraulic System Specifications
Specifications
A
HYDRAULIC SYSTEM SPECIFICATIONS
Auxiliary Pressure Compensated Pump
System Pressure.........................................................2,850 psi (19650 kPa)
Discharge Conveyor Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)
Storage Conveyor Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)
Elevator Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)
Fan Drive
Max fan speed.............................................................925 rpm
.....................................................................................max 3000 psi (20684 kPa)
Ground Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)