EasyManua.ls Logo

Weiler E1650 - Hydraulic System Specifications

Weiler E1650
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WEILER E1650 REMIXING TRANSFER VEHICLE
A-5
Hydraulic System Specifications
Specifications
A
HYDRAULIC SYSTEM SPECIFICATIONS
Auxiliary Pressure Compensated Pump
System Pressure.........................................................2,850 psi (19650 kPa)
Discharge Conveyor Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)
Storage Conveyor Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)
Elevator Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)
Fan Drive
Max fan speed.............................................................925 rpm
.....................................................................................max 3000 psi (20684 kPa)
Ground Drive
Charge Pressure .........................................................350 psi (2413 kPa)
System Pressure.........................................................6,090 psi (42000 kPa)