5 Service programs
Training manual Convotherm 4 77
Item Name Function Value
range
Default
setting
Units
10 04 Display settings
for oven values
Defines how cooking-chamber values are
displayed.
0 – Current values are displayed for 3 sec-
onds.
1 – Current values are displayed until
reclicked.
0 / 1 0 -
10 05 Display settings
for CTP values
Defines the display behaviour for CTP values
0 – Current values are displayed for 3 sec-
onds.
1 – Current values are displayed until
reclicked.
0 / 1 0 -
10 06 Resume
cooking
Defines whether the resume button is displayed
when Stop was used to interrupt cooking.
0 / 1 0 -
10 07 Number of shelf
levels
Defines the number of shelf levels in the cook-
ing chamber.
If this value is zero, a default value is used
according to the appliance size.
6.10 = 7 shelf levels
6.20 = 7 shelf levels
10.10 = 11 shelf levels
10.20 = 11 shelf levels
12.20 = 1 shelf level (loading trolley)
20.10 = 1 shelf level (loading trolley)
20.20 = 1 shelf level (loading trolley)
0 - 20 0 -
Cooking
Item Name Function Value
range
Default
setting
Units
20 05 Steam meas.
hysteresis, auto
steam
Used in the auto-steam temperature range.
Boiler appliances: 100 °C
0.2 - 10.
0
0.5 [°C]
20 06 Boiler temper-
ature adjust-
ment in auto
steam
Used in the auto-steam temperature range in
boiler appliances.
Depending on the geographical location, it may
not be possible to heat the boiler to 100 °C
0.2 - 30 3 [°C]
20 07 Oven tempera-
ture
in auto steam
(injection)
Used in steam temperature range.
Injection appliances: 96 °C - 100 °C
80.0 -
100.0
97 [°C]
20 14 Hold time for
steam satura-
tion
Hold time in minutes for steam saturation. 1 - 20 10 [min]
20 16 Steam meas-
urement, low
temp
steam
Used in the low-temp steam temperature range
for steam.
Please note: boiler appliance: 92 °C / injection
appliance: 87 °C
80.0 -
100.0
[°C]
20 17 Steam meas-
urement, auto
steam
Used in the auto-steam temperature range for
steam.
Please note: boiler appliance: 92-°C /
injection appliance: 87-°C
80.0 -
100.0
[°C]
20 18 Steam meas-
urement, quick
steam
Used in the quick-steam and steam temperature
range.
Please note: boiler appliance: 92 °C /
injection appliance: 87 °C
80.0 -
100.0
[°C]