5 Service programs
Training manual Convotherm 4 78
Calibration
Item Name Function Value
range
Default
setting
Units
30 01
CTP1 offset
Defines the offset for
core temperature probe 1
-8.0 - 8.0 0 [°C]
30 02
CTP2 offset
Defines the offset for
core temperature probe 2
-8.0 - 8.0 0 [°C]
30 03
CTP3 offset
Defines the offset for
core temperature probe 3
-8.0 - 8.0 0 [°C]
30 04
CTP4 offset
Defines the offset for
core temperature probe 4
-8.0 - 8.0 0 [°C]
30 05
Sous-vide offset Defines the offset for the sous-vide sensor -8.0 - 8.0 0 [°C]
HumidityPro
Item Name Function Value
range
Default
setting
Units
40 02 Pulse off time,
level 1
Defines the time period in which convection is
used to maintain the oven temperature (level 1).
1 - 60 25 [min]
40 03 Pulse off time,
level 2
Defines the time period in which convection is
used to maintain the oven temperature (level 2).
1 - 60 20 [min]
40 04 Pulse off time,
level 3
Defines the time period in which convection is
used to maintain the oven temperature (level 3).
1 - 60 15 [min]
40 05 Pulse off time,
level 4
Defines the time period in which convection is
used to maintain the oven temperature (level 4).
1 - 60 10 [min]
40 06 Pulse off time,
level 5
Defines the time period in which convection is
used to maintain the oven temperature (level 5).
1 - 60 5 [min]
Crisp&Tasty
Item Name Function Value
range
Default
setting
Units
50 01 Dehumidifi-
er-valve
opening delay
Defines the delay before opening the dehumidi-
fier valve after closing the appliance door or
reversing the fan direction.
0 - 10 2 [s]
50 02 Collector
drainage
pump, time
Defines the time period in which the
CS-chamber drainage pump is on.
0 - 30 5 [s]
50 03 Collector
drainage
pump, interval
Defines the time period in which the
CS-chamber drainage pump is off.
0 - 600 15 [s]
50 04
Cycle time Defines the time length of a Crisp&Tasty cycle. 0 - 300 60 [s]
50 05 Level 1: Dehu-
midifier valve
open time
Defines the time period in which the dehumidifi-
er valve shall be open
(Crisp&Tasty level 1).
0 - 300 12 [s]
50 06 Level 2: Dehu-
midifier valve
open time
Defines the time period in which the dehumidifi-
er valve shall be open
(Crisp&Tasty level 2).
0 - 300 24 [s]
50 07 Level 3: Dehu-
midifier valve
open time
Defines the time period in which the dehumidifi-
er valve shall be open
(Crisp&Tasty level 3).
0 - 300 36 [s]