5 Service programs
Training manual Convotherm 4 79
Item Name Function Value
range
Default
setting
Units
50 08 Level 4: Dehu-
midifier valve
open time
Defines the time period in which the dehumidifi-
er valve shall be open
(Crisp&Tasty level 4).
0 - 300 48 [s]
50 09 Level 5: Dehu-
midifier valve
open time
Defines the time period in which the dehumidifi-
er valve shall be open
(Crisp&Tasty level 5).
0 - 300 60 [s]
BakePro
Item Name Function Value
range
Default
setting
Units
60 01 Level 1: Mois-
ture input On
time
Defines the time period in which the moisture
input shall be on (BakePro level 1).
0 - 180 30 [s]
60 02 Level 1: Fan Off
time
Defines the time period in which the fan shall be
off (BakePro level 1).
0 - 180 60 [s]
60 03 Level 2: Mois-
ture input On
time
Defines the time period in which the moisture
input shall be on (BakePro level 2).
0 - 180 45 [s]
60 04 Level 2: Fan Off
time
Defines the time period in which the fan shall be
off (BakePro level 2).
0 - 180 75 [s]
60 05 Level 3: Mois-
ture input On
time
Defines the time period in which the moisture
input shall be on (BakePro level 3).
0 - 180 60 [s]
60 06 Level 3: Fan Off
time
Defines the time period in which the fan shall be
off (BakePro level 3).
0 - 180 90 [s]
60 07 Level 4: Mois-
ture input On
time
Defines the time period in which the moisture
input is shall be on (BakePro level 4).
0 - 180 75 [s]
60 08 Level 4: Fan Off
time
Defines the time period in which the fan shall be
off (BakePro level 4).
0 - 180 105 [s]
60 09 Level 5: Mois-
ture input On
time
Defines the time period in which the moisture
input shall be on (BakePro level 5).
0 - 180 90 [s]
60 10 Level 5: Fan Off
time
Defines the time period in which the fan shall be
off (BakePro level 5).
0 - 180 120 [s]
Regenerating
Item Name Function Value
range
Default
setting
Units
70 04 Plate regener-
ating: Steam
meas. max
temp
Defines the maximum bypass temperature
during steam generation in plate regenerating
mode.
70.0 -
100.0
95 [°C]
70 05 Plate regener-
ating: convec-
tion time
Defines the time length of convection heating in
plate regenerating mode.
90 - 140 120 [s]
70 06 Plate regener-
ating: min. time
for steaming
Defines the minimum time length for steam
heating in plate regenerating mode.
90 - 140 100 [s]