5 Service programs
Training manual Convotherm 4 80
Item Name Function Value
range
Default
setting
Units
70 07 Plate regener-
ating: max. time
for steaming
Defines the maximum time length for steam
heating in plate regenerating mode.
90 - 140 100 [s]
70 09 À la Carte
regenerating:
convection time
Defines the time length of convection heating in
à la Carte regenerating mode.
5 - 60
15 (electric)
32 (gas)
[s]
70 10 À la Carte
regenerating:
min. time for
steaming
Defines the minimum time length for steam
heating in à la Carte regenerating mode.
1 - 60
2 (electric)
22 (gas)
[s]
70 11 À la Carte
regenerating:
max. time for
steaming
Defines the maximum time length for steam
heating in à la Carte regenerating mode.
1 - 60
5 (electric)
25 (gas)
[s]
70 15 Banquet
regenerating:
steam meas.
min temp
Defines the minimum bypass temperature
during steam generation in banquet regenerat-
ing mode.
40.0 -
90.0
50 [°C]
70 16 Banquet
regenerating:
Steam meas.
max temp
Defines the maximum bypass temperature
during steam generation in banquet regenerat-
ing mode.
80.0 - 12
2.0
95.0 [°C]
70 17 Banquet
regenerating:
convection time
Defines the time length of convection heating in
banquet regenerating mode.
60 - 300 120 [s]
70 18 Banquet
regenerating:
min. time for
steaming
Defines the minimum time length for steam
heating in banquet regenerating mode.
60 - 300 100 [s]
70 19 Banquet
regenerating:
max. time for
steaming
Defines the maximum time length for steam
heating in banquet regenerating mode.
60 - 300 100 [s].
PID
Item Name Function Value
range
Default
setting
Units
80 01 Control loop
gain
Parameter for tuning the proportional gain 0 - 100 0 -
80 02
Control time Parameter for tuning the integral time 0 - 100 0 -
80 03
Derivative Time Parameter for tuning the derivative time 0 - 100 0 -
Cleaning
Item Name Function Value
range
Default
setting
Units
90 01 Resume after
cleaning
stopped
Defines the number of attempts to resume
cleaning when there is a cleaning problem.
0 - 10 10
[Quanti-
ty]