5 Service programs
Training manual Convotherm 4 84
Item Name Function Value
range
Default
setting
Units
160 02 Run-on time
after appliance
door closed
Defines the length of time that the extraction
hood shall continue running at maximum rate
after the appliance door has been closed.
0 -
63335
20 [s]
160 03 Run-on time
after
dehumidifier
valve closed
Defines the length of time that the extraction
hood shall continue running at maximum rate
after the valve has been closed.
0 -
63335
20 [s]
160 04 Start-up phase
at end of recipe
Defines the time at which the extraction hood
shall start running before the cooking profile has
finished.
Please note:
0 means that the extraction hood starts running
when the appliance door is open.
0 - 60 5 [s]
160 05 Extractor hood
run-on time
Defines the operating mode of the extraction
hood if it is installed in the oven
(EHStandbyMode_t).
After high/low speed is deactivated (according
to the various modes and special events for the
extraction hood), the hood continues to run at
high speed for a certain length of time (set by
adjustable parameter “Run Time After Switch
Off”: default = 20 s) before finally turning off.
0 -
63335
20 [sec.]
Cool down
Item Name Function Value
range
Default
setting
Units
170 01 Cool down
present
Defines whether or not Cool down or preheat is
available.
0 / 1 1 -
170 02 Temperature
tolerance
Defines by how much the actual temperature
shall be higher/lower than the target tempera-
ture in order to actuate Cool down/preheat.
0 - 300 30 [°C]
170 04 Fan
speed
Defines the fan speed for the Cool down func-
tion.
0 - 100 40 [%]
Vapour condenser
Item Name Function Value
range
Default
setting
Units
180 01 Vapour
condenser On
Defines the temperature in the condensation
unit (Vapour Reduction System) above which
water is injected until the temperature has
dropped back below the offTemp temperature.
30 - 130 60 [°C]
180 02 Vapour
condenser Off
Defines the temperature in the condensation
unit (Vapour Reduction System) below which
water injection is stopped.
30 - 100 40 [°C]