5 Service programs
Training manual Convotherm 4 85
Grease filter
Item Name Function Value
range
Default
setting
Units
185 01 Min. oven
temperature
Defines the minimum cavity temperature above
which grease separation applies.
30 - 250 120 [°C]
185 02 Min. bypass
temperature
Defines the minimum bypass temperature
above which grease separation applies.
30 - 100 70 [°C]
Signal tower
Item Name Function Value
range
Default
setting
Units
Mode for
buzzer
Mode for color
setting
Miscellaneous
Item Name Function Value
range
Default
setting
Units
190 01 Injection
pressure-switch
delay
0 - 255 8 [sec.]
190 02 Filter change
message
Defines whether or not a message is displayed
regarding the capacity of the water treatment
filter.
0 / 1 1 -
190 03 Filter change
indicator
Defines when the water treatment filter needs to
be changed.
5 - 480 10 -
190 04 Service phone
number
Stores the Service contact number in the "big
endian" format.
0 -
63535
0 -
190 05 Dehumidifier
valve
pressure
equalization
Defines the length of time that the dehumidifier
valve is open after the appliance door has been
closed.
Please note: takes priority over the Crisp&Tasty
function.
0 - 60 0 [s]
190 06 Drainage pump
cooling
Defines the length of time for which the
wastewater cooling pump runs when
Crisp&Tasty is active.
0 -
63535
1800 [s]
Default settings
The 'Default settings' button resets all the adjustable parameters to the factory presets.