73
eikon e1s
Service and repair guide
Temperature band setting
5. Select the ‘temperature band symbol.
6. Select the required temperature band checkbox, shown by a green
checkmark.
Note: Generally, the lowest practical Temp Band should be chosen. If the
set cavity temperature falls by more than the selected temperature band
value, the ready-to-cook mode and the temperature band are deactivated
until the cavity reaches the preset preheat temperature.
Change setting / service access password
7. Select the key symbol to change the passwords of the appliance.
8. Select the appliance settings or service symbol.
9. Enter the existing password and press the green checkmark to
confirm.
10. Enter a new password and press the green checkmark.
11. Confirm the new password and press the green checkmark again.