6.
Readings must be below 5 mW/cm² to pass the microwave leakage test.
Any leakage that is observed in terms of the level and position on the appliance should be recorded and kept with
the appliance user documentation.
If a level greater than 5 mW/cm² is observed, check for damage to door, door seals, panel work
and replace as necessary, then re-test. If not resolved, contact your local Merrychef representative.
Don't use the appliance hereafter.