Remove Integral Voltage Regulator:
Remove two screws securing integral voltage regulator to rear housing.
NOTE:
Alternators with remote voltage regulator systems will have a space part mounted to the
rear housing instead of the
integral voltage regulator.
REMOVING
VOLTAGE
REGULATOR
Remove Diode-Trio (Field Diode) and Rectifier Diode Bridge:
(2)
REGULATOR
MOUNTING SCREWS
The diode-trio and rectifier diode bridge are detached as
an
assembly. Remove cone lockout from
positive output (B+)
terminal. Straighten
B+
strap. Remove three terminal screws and four diode-
trio mounting screws. Detach assembly from rear housing and separate diode-trio assembly from
rectifier bridge. See illustration below.
(4) MOUNTING
SCREW
CONE LOCKNUT
AND
B+
STRAP
REMOVING DIODE-TRIO
AND RECTIFIER DIODE BRIDGE.
69