EasyManua.ls Logo

WinGD W-X82 - Page 230

WinGD W-X82
548 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation08501/A1
Winterthur Gas & Diesel Ltd.
20/ 39
Failure text
ME servo oil pressure high (ID 19)
FCM20 No. LED Failure ID Display
Indication #01 and #02 AI2 19 19
Cause Servo oil pressure is 15 bar more than the setpoint, engine speed is more than 8% of nominal
speed (failure signal is released after 5 seconds).
Remark: No failure is shown during the conditions that follow:
Slow turning, air run and control oil meas. fail.
Pressure controllers were not adjusted in the servo oil pumps after an overhaul.
Dirt particles prevent the function of a pressure controller.
Procedure Clean / adjust the pressure controllers in servo oil pumps.
Failure Text ME servo oil pressure low (ID 20)
FCM20 No. LED Failure ID Display
Indication #01 and #02 AI2 20 20
Cause Servo oil pressure is 15 bar less than the setpoint. The engine speed is more than 8% of
nominal speed (failure signal is released after 10 seconds).
Remark: No failure is shown during the conditions that follow:
Slow turning, air run, shut-down and servo oil pressure very low, control oil meas. fail.
Procedure Do a check of the oil pressure downstream of the automatic filter.
Do a check of the control signals and cables to the servo oil pumps for correct connections and
/ or damage.
Repair or replace damaged cables.
Make sure that the safety valve 4.23 open.
The pump drive shaft 4.50 is broken (pump temperature low, no vibrations) or the pump is
defective.
The HP pipes have leaks between the collector block and the servo oil rail. Do a check for a
leakage alarm.
Repair the leaks.
If necessary, replace the related pressure controller (CV7221C, CV7223C).
Remark: In dangerous conditions, temporarily set to off the injection and exhaust valve
operation on cylinders 1 or 2 to increase the servo oil pressure
Attention: Do not set the cylinders to off in their firing order sequence. Do not operate the
engine at or near the barred speed range
Failure Text ME servo oil pump #1 fail. (ID 26)
FCM20 No. LED Failure ID Display
Indication #03 PWM 26 26
Cause The setpoint pressure controller of the servo oil pump actuator CV7221C is more than 100
mA (failure signal is released after 30 seconds)
Procedure In E85, set the FCM20 #03 to off.
Do a check of the connection on the servo oil pump actuator CV7221C.
If necessary, replace the cables and connections.
Make sure that the cables and connections between pump #1 and E95.03 are correct.
If necessary, replace the servo oil pump actuator CV7221C.
In E85, set the FCM20 #03 to on.
2014
Failures and Defects of WECS Components

Table of Contents