Failure Text
ME cylinder lubrication malfunction cylinder #nn
ALM20 No. LED On / Off Code
Indication #01 to #09 Fail Red Two times each
interval
Cause A cable is broken between an ALM20 (plug X1, terminals 13 and 14) and the pressure trans-
mitter (PT3131C to PT3139C).
Procedure Do a check of the cables on the related ALM20. If the cables are serviceable, the pressure
transmitter has a malfunction
Make sure that the related cable connections between ALM20 (plug X1, terminals 13 and 14)
and pressure transmitter are connected correctly and have no damage.
If necessary, repair or replace damaged cables.
If necessary, replace the related pressure transmitter (PT3131C to PT3139C) if necessary
(see 08201 Cylinder lubrication)
ALM20 No. LED On / Off Code
Indication #01 to #09 Power Off None
Cause No power supply to an ALM20
Procedure In E85, do a check of the power supply units U500 / U501 and their circuit breakers F500 /
F501
If a green LED DC OK shows, do a check of the cables on the related ALM20 (plug X2,
terminals 21 and 22 or 23 and 24)
If a green LED DC OK flashes, do a check of the cables on the related ALM20 and/or the
related ALM20 (do a check for a short circuit)
Make sure that the cable between E85 and the related ALM20 (plug X2, terminals 21 and 22
or 23 and 24) is correctly connected and has no damage.
If necessary, repair or replace damaged cables.
Replace the related ALM20 (if there is a short circuit)