EasyManua.ls Logo

WinGD W-X82 - Page 248

WinGD W-X82
548 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation0850−1/A1
Winterthur Gas & Diesel Ltd.
38/ 39
Failure Text
ME cylinder lubrication malfunction cylinder #nn
ALM−20 No. LED On / Off Code
Indication #01 to #09 CAN1 and/or CAN2 Red None
Cause LED indication on one module: a cable is broken on the plug X2 on the related ALM−20.
LED indication on all modules: CAN Bus #1 / #2 malfunction.
Procedure ⇒ LED indication on one module: Do a check of the cables on the plug X2 (terminals 25 and 26
CAN #1 and/or terminals 27 and 28 CAN #2 on the related ALM−20 for correct connections
and / or damage.
⇒ LED indication on all modules: Do a check of the CAN module bus from the last and the last but
one cylinder on the FCM−20 (plug X22, terminals 55 and 56) for correct connections and / or
damage.
⇒ If necessary, repair or replace damaged cables.
⇒ If necessary, replace the ALM−20.
ALM−20 No. LED On / Off Code
Indication #01 to #09 VLV and Fail Red None
Cause The cables between the ALM−20 (plug X1, terminals 11 and 12) and the 4/2-way solenoid
valve (ZV7131C to ZV7139C) have a short circuit.
Procedure ⇒ Do a check of the related cables. If the cables are serviceable, the 4/2-way solenoid valve has
a malfunction (coil R~18 ohm).
⇒ Make sure that the related cable between ALM−20 (plug X1, terminals 11 and 12) and the
4/2-way solenoid valve is correctly connected and has no damage.
⇒ If necessary, repair or replace damaged cables.
⇒ If necessary, replace the related 4/2-way solenoid valve (see 0820−1, paragraph 2 Cylinder
lubrication).
ALM−20 No. LED On / Off Code
Indication #01 to #09 VLV and Fail Red None / 1x
Cause A cable is broken between the ALM−20 (plug X1, terminals 11 and 12) and the 4/2-way
solenoid valve (ZV7131C to ZV7139C).
Procedure ⇒ Do a check of the related cables. If the cables are serviceable, the 4/2-way solenoid valve has
a malfunction (coil R~18 ohm).
⇒ Make sure that the related cable between the ALM−20 (plug X1, terminals 11 and 12) and the
4/2-way solenoid valve is correctly connected and has no damage.
⇒ If necessary, repair or replace damaged cables.
⇒ If necessary, replace the related 4/2-way solenoid valve (see 0820−1, paragraph 2 Cylinder
lubrication)
ALM−20 No. LED On / Off Code
Indication #01 to #09 Fail Red None
Cause A short circuit of the cables from ALM−20 (plug X1, terminals 13 and 14) to the pressure
transmitter (PT3131 to PT3139C).
Procedure ⇒ Do a check of the cables on the related ALM−20. If the cables are serviceable, the pressure
transmitter has a malfunction.
⇒ Make sure that the related cable between the ALM−20 (plug X1, terminals 13 and 14) and
pressure transmitter is connected correctly and has no damage.
⇒ If necessary, repair or replace damaged cables.
⇒ If necessary, replace the related pressure transmitter (PT3131C to PT3137C) (see 0820−1
paragraph 2 Cylinder lubrication).
2014
Failures and Defects of WECS Components

Table of Contents