Operation
72181/A1
Winterthur Gas & Diesel Ltd.
19/ 19
8.4 Lubricating Oil Feed Rate Adjustment
It is possible to adjust the lubricating oil feed rate in steps of 0.1 g/kWh. Use the user
parameters in the columns Supply Rate and Adjustment for one cylinder, or for all
cylinders (see 40023, paragraph 1.1).
For more data about the adjustment of the lubricating oil feed rate, see 72183.
For data about the guide feed rates for running-in of new cylinder liners and piston
rings, see 04101, paragraph 4, Cylinder lubricating oil feed rate, and paragraph 5,
Running-in sequence.