Maintenance27221/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
2/ 8
2. Checking an injection valve
Before commissioning the instructions and directions of the test bench manufac-
turer must be observed.
From time to time check the pressure gauges of the test bench with a master pres-
sure gauge and adjust them if necessary.
Remark: The work station must be clean; welding and grinding should not be done
nearby!
Remove combustion residues and clean nozzle tip externally with a brass
wire brush.
Place injection valve 1 with nozzle tip pointing downwards into support 20 of
test bench 94272 and fasten it with two Allen screws 2 and spring cages 24.
Tighten high pressure hose 21 of the test bench with connecting piece
94272b.
Start the test bench following the proper manufacturer’s instructions.
Bring the injection valve to spray with a few short pump jerks, and then ob-
serve at what pressure the injection valve opens, applying slow, equal pump
jerks.
Danger of injuries! Never hold fingers or hands directly before the spray holes of
the nozzle tip!