Maintenance64201/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
2/ 3
The air flaps 7 in scavenge air receiver
and the fixed support 5 (Fig. ’A’) can be
removed after the screws 11 have
been unscrewed.
11
5
3
12
II
I
10
4
13
7
8 8
9
12
11
1211
12
14
018.183/09
II
WCH01063
2. Cleaning the scavenge air receiver
Scavenge air receiver 2 should be checked for cleanliness at regular intervals (see
03801), however, always after a piston overhaul or after regular maintenance in
the piston underside.
In particular check whether water drain piping 10 from the scavenge air receiver is
not clogged, so that a permanent drainage is assured during operation.
During a major overhaul check O-ring and spring preload of relief valve 9 as fol-
lows:
Gap between metal must be visible (O-ring intact).
Preload distance x must correspond to the value in Fig. ’B’.
If any defect or heavy rust is visible, replace the relief valve.
Remark: Do not open the relief valve with disc springs! In case of any damages or
malfunctions please contact the manufacturer or Wärtsilä Switzerland Ltd.