Maintenance87331/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
2/ 4
2. Fitting
Fitting procedure is analogous to the removal but in reverse sequence.
Before fitting HP pipe 4 check whether its claws 5 are screwed on properly, i.e. the
HP pipe must protrude by ’x’= 8 mm compared to the claw.
Measurement ’x’ can be adjusted by turning the claw using special spanner 94874.
Fit HP pipe.
Apply Never-Seez NSBT-8 to threads of screws 8 and tighten them crosswise
with a torque of 40 Nm.
Tighten drain screws 9.
B
x
C
I - I
I
016.000/07
7
6
5
4
11
8
9
WCH02284
I
5
6
7
4
5
6
7
4
x
94874
AF24
DRAWN WITH
STAR PIPE
12
2013-08
HP Pipe to Injection Valve: Removing, Fitting and Regrinding of Sealing Faces