Maintenance0380−1/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
6/ 8
Group Component Work to be carried out Intervals
6708−1 Water separator − Check condensate collector through sight glass
(see Operating Manual 8345−1)
daily
− Check condensate collector for free passage
(see Operating Manual 8345−1)
1500−3000 Op. h
− Check water separator elements (if necessary
clean them)
1500−3000 Op. h
− Remove water separator for general overhaul as required
7
7218−1 Lubricating pump
and accumulator
(Pulse lubrication)
− General maintenance works according to instructions
of equipment
manufacturer
− Checking gas (nitrogen) pre-charge pressure:
CLU4−C min. 30 bar / max. 35 bar
directly after installation of a new accumulator −>
then at least once in first week after start-up −>
afterwards −>
every three months
8
8135−1
Exhaust Waste
Gate (LLT)
− During a longer operation period at low engine
load, manually open butterfly valve at least once
per week (see Operating Manual 8135−1)
− General inspection
according to instruction
of valve manufacturer
Servo oil
automatic filter
− Follow manufacturer’s instructions
Starting air
piping
− Drain (de-water) before and after every
manoeuvering period
Pressure gauges
and pyrometers
− Compare and calibrate according to master
instruments
6000−8000 Op.h
Fuel and
lubricating oil
filters
− Clean or replace filter elements
(depending on make, follow manufacturer’s in-
structions)
as required
Pipe holders − Check fastenings periodically, if necessary
retighten screws
(first time after 100 Op.h, then half yearly)
as required
8447−1 HP servo oil pipe − Regrind sealing faces as required
8460−1 Hydraulic pipe for
exhaust valve
drive
− Regrind sealing faces as required
2013 / V2
Inspection and Overhaul Intervals (Guidelines)