Operation Manual simco
®
drive
Revision: 11a 4022-D033499 en-21
日本語
Connection
Properties
Unit
Minimum
value
Nominal
value
Maximum
value
DOUTx
Output voltage
V DC
18
24
26
Output current
mA DC
40
Output resistance
kOhm
1
1,5
2
Refresh rate
Hz
1
VCC24
Voltage
V DC
20
24
28
Current
mA DC
80
GND
6.3.7 X5: Diagnostic interface RS232
Figure
Pin
no.
Signal
Function
Input/output
1
TxD
Transmit Data
Output
2
RxD
Receive Data
Input
3
GND
Reference
ground
-
4
N.C.
Plug type on drive amplifier: M12, 4-pin, female, A-coded
Connection
Properties
Unit
Minimum
value
Nominal
value
Maximum
value
TxD / RxD
Baud rate
baud
115200
6.3.8 X6/X7: Fieldbus interface CANopen
The CAN reference ground is identical to the logic reference ground.
The CAN signals are galvanically isolated from the power of the drive amplifier.
Figure
Pin no.
Signal
Function
1
Shield
Screen
2
N.C.
3
CAN_GND
CAN reference ground
4
CAN_H
CAN High
5
CAN_L
CAN Low
Plug type on drive amplifier: M12, 5-pin, female, A-coded at X6 and X7
Connection
Properties
Unit
Minimum
value
Nominal
value
Maximum
value
Baud rate
kbaud
100
500
1000