7 Startup and operation
7.1 Safety instructions
For secure application of the drive amplifier, the following regulations must be observed:
Connection and operating instructions
Local regulations
EC regulations and the EC Machinery Directive
The housing temperature on the drive amplifier can reach
80 °C during operation.
Wait until the housing temperature has cooled down to 40 °C
before touching the drive amplifier.
Before startup, the machine manufacturer must prepare a
risk assessment for the machine and take appropriate
measures so that unforeseen movements cannot lead to
personal injury or property damage.
Only technicians with extensive experience with electrical
and electronic systems and drive technology may start up
the drive amplifier.
7.2 Startup software
For parameterization and startup of the drive, the startup software motion gui is available as
well as an interactive, html-based help.
The startup software motion gui is used to change and save the operating parameters of the
drive amplifier. The connected drive amplifiers can be put into operation with the help of
software.
In the html-based help, all parameters and the function of the drive amplifier are described.
Incorrect parameterization can cause uncontrolled
movements. For this reason, never change parameters
whose meaning you do not completely understand.