Commissioning
20 | WOLF GmbH 3066510_202108
5.3.1 Use as remote control
If the RM-2 detects another system controller (BM or BM-2), the
RM-2 will be used to operate an assigned heating/mixing circuit or
all circuits (program selection and set value). The RM-2 provides a
screen which can be used to select the heating/mixing circuit to be
controlled (see Section 10.2). The RM-2 will return to the standard
display after the circuit is selected.
5.3.2 Use as controller
If no other system controller is detected, the RM-2 will function as
a complete (room temperature) controller for the heating and/or
ventilation unit. No additional conguration is required. The RM-2 will
then return to the standard display (see Section 10.3).
When used as a controller, the RM-2 calculates the set ow
temperature of the heating appliance on the basis of the
room temperature. The ventilation level can be congured for
the ventilation unit.
5.3.3 Changing the function of the RM-2 / RM-2 Wireless
Once the RM-2 has stored its function (remote control (incl. heating /
mixer circuit assignment) or controller), this function will be stored in
the RM-2 until the device is reset.
The RM-2 must be reset before it can be added to a new system
conguration (see page 22, para.: 6.2.)