Room temperature controller functions
34 | WOLF GmbH 3066510_202108
8.6.3 Time program
► Press the
key
– All other settings are covered in the images in Section 10.5 of the
Appendix.
– General info about time programs.
Separate day or week programs (depending on parameter P 03)
exist for heating, DHW and ventilation:
– Heating: The program switches between raised (ON) and lowered
(OFF) operation.
– DHW: The program switches between permanent operation (ON)
and standby (OFF). The circulation system operates accordingly.
– Ventilation: The program switches between the ventilation levels
of nominal ventilation (ON) and reduced ventilation (OFF).
Up to three switching times (three “ON” switching times and 3 “OFF”
switching times) can be congured per day for each program:
Switching time
Factory setting
Status Time
Heating
Time
Domestic hot
water
Time
Ventilation
1 Start (ON) 6:00 6:00 6:00
1 End (OFF) 22:00 22:00 22:00
Switching time
Setting
Status Time
Heating
Time
Domestic hot
water
Time
Ventilation
1 Start (ON)
1 End (OFF)
2 Start (ON)
2 End (OFF)
3 Start (ON)
3 End (OFF)
Table 8.1 Switching times