Remote control functions
28 | WOLF GmbH 3066510_202108
7.4 Holiday mode
Press key in the standard display
Set the duration using the
+
+
-
-
keys (15 minutes – 99 days)
Press
to enter and conrm
Press
to cancel. The RM-2 will also return to the menu
automatically if not used for one minute (RM-2 Wireless: 30
seconds)
Exit holiday mode
Ends automatically after the time period
Manual deactivation:
Press the holiday key, “OFF” will appear in the display
Press
to conrm
Symbol Function
Holiday mode: Economy/reduced operation mode
(heating and DHW) for a predened period (15 min. to 99
days)
7.5 Interaction between the RM-2 and the heating control
unit
The set temperature and the actual room temperature have different
effects depending on how the system controller (BM/BM-2) is
congured.
Weather-compensated control unit:
Actual room temperature has no effect on the control unit, as it
is simply a weather-compensated unit. Any change to the set
temperature (±4) has a direct effect on the heating curve of the
system controller.
Room inuence / room controller only:
The actual room temperature and the set temperature are used
for ow temperature control purposes. The absolute set room
temperature can be set as the “Day temperature” on the system
controller. The day temperature can be changed by ±4K by
adjusting the set value correction on the RM-2.