Room temperature controller functions
3066510_202108 WOLF GmbH | 31
8.6 Menu
Press key in the standard display
8.6.1 Display list
Navigation as per remote control!
Index Meaning Unit
A01 Set ow temperature °C
A02 Current ow temperature °C
A03 Current DHW temperature °C
8.6.2 Parameter list
Navigation as per remote control!
Index Meaning
Setting
range
Factory
setting
P 01 Time 00:00 – 23:59 00:00
P 02 Day of week
1 – 7
(Monday –
Sunday)
1
P 03 Time program type
0 – 1
(0 = day program
1 = week
program)
0
P 04 Room temperature offset -5 K to +5 K 0
P 10 Set DHW temperature 20°C – 80°C 50
P 11 Pasteurisation function 0 – 1 0
P 12/
HG15*
Cylinder hysteresis 1K to 30K 5 K
P 13 DHW quick start 0 – 1 0
P 13/
HG11*
DHW quick start 10 – 60°C 10°C
P 14/
HG23*
Maximum DHW
temperature
60°C – 80°C 65°C

Table of Contents