Parameter Details
2
2.2 A: Initialization Parameters
YASKAWA TOEPYAIGA5002A GA500 Programming 157
A2: User Parameters
You can register frequently used parameters and recently changed parameters here to access them quickly. Use Setup
Mode to show the saved parameters.
A2-01 to A2-32: User Parameters 1 to 32
No.
(Hex.)
Name Description
Default
(Range)
A2-01 to A2-32
(0106 - 0125)
User Parameters 1 to 32
You can select a maximum of 32 parameters for the drive and save the values to parameters A2-01 to
A2-32. Use Setup Mode to show the saved parameters. You can immediately access these saved
parameters.
Parameters in General-
Purpose Setup Mode
(Determined by A1-06)
Note:
When the A1-06 [Application Preset] value changes, the settings for A2-01 to A2-32 change.
You must set A1-01 = 1 [Access Level Selection = User Parameters] to access parameters A2-01 to A2-32.
When A1-07 = 1 or 2 [DriveWorksEZ Function Selection = DWEZ Enabled or Enabled/Disabled wDigital Input], the drive saves qx-xx
[DriveWorksEZ Parameters] to A2-01 to A2-32.
The drive saves these parameters to A2-01 to A2-32.
The drive saves a maximum of 32 parameters.
Note:
Set A1-01 = 2 [Advanced Level] or A1-01 = 3 [Expert Level] to save the necessary parameters.
The drive automatically saves changed parameters to A2-17 to A2-32.
Note:
Set A2-33 = 1 [User Parameter Auto Selection = Enabled].
A2-33: User Parameter Auto Selection
No.
(Hex.)
Name Description
Default
(Range)
A2-33
(0126)
User Parameter Auto
Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User Parameters 17 to
32].
Determined by A1-06
(0, 1)
0 : Disabled: Manual Entry Required
Set User Parameters manually.
1 : Enabled: Auto Save Recent Parms
The drive automatically registers changed parameter A2-17 to A2-32. The drive automatically saves the most recently
changed parameter to A2-17, and saves a maximum of 16 parameters. After the drive registers 16 parameters, when
you save a new parameter, the drive will remove a parameter from the User Parameter list to make space for the new
parameter. The drive removes parameters with First In, First Out.
Use Setup Mode to show the saved parameters.
Note:
In General-Purpose Setup Mode, the drive saves parameters starting with A2-27 because the drive saves parameters A2-26 and lower by
default.