EasyManua.ls Logo

YASKAWA GA500 series - PM Motor Protection Settings

YASKAWA GA500 series
526 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.9 F: Options
44 YASKAWA TOEPYAIGA5002A GA500 Programming
F7: Communication Options
No.
(Hex.)
Name Description
Default
(Range)
Ref.
F7-01
(03E5)
IP Address 1
Sets the first octet of the IP Address for the device that is connecting to the network.
Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
192
(0 - 255)
280
F7-02
(03E6)
IP Address 2
Sets the second octet of the IP Address for the device that is connecting to the network.
Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
168
(0 - 255)
280
F7-03
(03E7)
IP Address 3
Sets the third octet of the IP Address for the device that is connecting to the network.
Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
1
(0 - 255)
280
F7-04
(03E8)
IP Address 4
Sets the fourth octet of the IP Address for the device that is connecting to the network.
Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a
different IP address for each drive on the network.
Also set parameters F7-01 to F7-12.
20
(0 - 255)
280
F7-05
(03E9)
Subnet Mask 1
Sets the first octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
255
(0 - 255)
280
F7-06
(03EA)
Subnet Mask 2
Sets the second octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
255
(0 - 255)
281
F7-07
(03EB)
Subnet Mask 3
Sets the third octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
255
(0 - 255)
281
F7-08
(03EC)
Subnet Mask 4
Sets the fourth octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
0
(0 - 255)
281
F7-09
(03ED)
Gateway Address 1
Sets the first octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
192
(0 - 255)
281
F7-10
(03EE)
Gateway Address 2
Sets the second octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
168
(0 - 255)
281
F7-11
(03EF)
Gateway Address 3
Sets the third octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
1
(0 - 255)
281
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents