EasyManua.ls Logo

YASKAWA GA500 series - H2 MFDO Parameters

YASKAWA GA500 series
526 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
2
2.8 H: Terminal Function Selection
YASKAWA TOEPYAIGA5002A GA500 Programming 311
Figure 2.71 Functional Block Diagram of Logical Operation Output for MFDO 1
Table 2.57 MFDO Logical Operation Table
Logical Operation Selection
Logical Operation Expression Logical Operation Notation
H2-61, H2-64, H2-67
0 A=B=1
1 A=1 or B=1
2 A=0 or B=0
3 A=B=0
4 A=B A=B
5 A != B
6
AND(A, )
7
OR(A, )
8 - On
Note:
If you use the function to output logical calculation results, you cannot set H2-01 to H2-03 = 1xx [Inverse Output of xx]. If you do, the drive
will detect oPE33 [Digital Output Selection Error].
When you do not use H2-60, H2-63, and H2-66, set them to F. The through mode function is not supported.
H2 MFDO Parameters
H2-01: Term MA/MB-MC Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H2-01
(040B)
Term MA/MB-MC Function
Selection
Sets the function set for MFDO terminal MA-MC or MB-MC.
E
(0 - 1FF)
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in through mode.
H2-02: Term P1-C1 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H2-02
(040C)
Term P1-C1 Function
Selection
Sets the function for MFDO terminal P1-C1.
0
(0 - 1FF)
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in through mode.
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA500 series

Related product manuals