3.2 Overview of Keypad Components and Functions
462 YASKAWA TOEPYAIGA5002A GA500 Programming
Set up the Drive with General-Purpose Setup Mode
Drive parameters are in letter groups from A to U. Setup Mode contains only the most frequently used
parameters to help you set up the drive more easily.
Figure 3.5 Parameters in General-Purpose Setup Mode
Set up the Drive with General-Purpose Setup Mode on page 462 shows the parameters available in Setup Mode. To
access parameters not shown in the Setup Mode, use the menu.
Table 3.2 Parameters in General-Purpose Setup Mode
User Parameters Parameter Name
A2-01 A1-02 Control Method Selection
A2-02 b1-01 Frequency Reference Selection 1
A2-03 b1-02 Run Command Selection 1
A2-04 b1-03 Stopping Method Selection
A2-05 C1-01 Acceleration Time 1
A2-06 C1-02 Deceleration Time 1
A2-07 C6-01 Normal / Heavy Duty Selection
A2-08 C6-02 Carrier Frequency Selection
A2-09 d1-01 Reference 1
A2-10 d1-02 Reference 2
A2-11 d1-03 Reference 3
A2-12 d1-04 Reference 4
A2-13 d1-17 Jog Reference
A2-14 E1-01 Input AC Supply Voltage
A2-15 E1-03 V/f Pattern Selection
A2-16 E1-04 Maximum Output Frequency
A2-17 E1-05 Maximum Output Voltage
A2-18 E1-06 Base Frequency
A2-19 E1-09 Minimum Output Frequency
A2-20 E1-13 Base Voltage
A2-21 E2-01 Motor Rated Current (FLA)
A2-22 E2-04 Motor Pole Count
A2-23 E2-11 Motor Rated Power
A2-24 H4-02 Terminal AM Analog Output Gain