Parameter Details
2
2.8 H: Terminal Function Selection
YASKAWA TOEPYAIGA5002A GA500 Programming 309
Note:
You cannot set values 90 to 96 for inverse output.
■ 9F: DWEZ Disable
Setting Value Function Description
9F DWEZ Disable
Sets operation of the DriveWorksEZ program saved in the drive.
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Digital input] to use this function.
ON : Disabled
OFF : Enabled
■ 101 to 19F: Inverse Input of 1 to 9F
Setting Value Function Description
101 to 19F Inverse Input of 1 to 9F Sets the function of the selected MFDI to operate inversely. To select the function, enter “1xx”, where the “xx” is the function setting
value.
For example, to use the inverse input of E [ASR Integral Reset], set H1-xx = 10E.
Note:
You cannot use inverse input for all functions. Refer to Table 2.49 for more information.
◆ H2: Digital Outputs
H2 parameters set the MFDO terminal functions.
■ H2-01 to H2-03 Terminal MA/MB-MC, P1-C1, P2-C2 Function Selection
The drive has four MFDO terminals.Table 2.54 shows the default function settings for the terminals.
Table 2.54 MFDO Terminals Default Function Settings
No. Name Default Function
H2-01
Term MA/MB-MC Function Selection
(Contact)
E Fault
H2-02 Term P1-C1 Function Selection 0 During Run
H2-03 Term P2-C2 Function Selection 2 Speed Agree 1
Refer to Table 2.55 to set H2-xx [MFDO Function Select].
Table 2.55 MFDO Setting Values
Setting Value Function Reference
0 During Run 318
1 Zero Speed 318
2 Speed Agree 1 319
3 User-Set Speed Agree 1 319
4 Frequency Detection 1 320
5 Frequency Detection 2 320
6 Drive ready 321
7 DC Bus Undervoltage 321
8 During Baseblock (N.O.) 321
9 Frequency Reference from Keypad 321
A Run Command Source 322
B Torque Detection 1 (N.O.) 322
Setting Value Function Reference
C Frequency Reference Loss 322
D Braking Resistor Fault 322
E Fault 322
F
*1
Not Used 322
10 Alarm 322
11 Fault Reset Command Active 323
12 Timer Output 323
13 Speed Agree 2 323
14 User-Set Speed Agree 2 323
15 Frequency Detection 3 324
16 Frequency Detection 4 324
17 Torque Detection 1 (N.C.) 325