Parameter List
1
1.10 H: Terminal Functions
YASKAWA TOEPYAIGA5002A GA500 Programming 65
H6: Pulse Train Input/Output
No.
(Hex.)
Name Description
Default
(Range)
Ref.
H6-01
(042C)
Terminal RP Pulse Train
Function
Sets the function for pulse train input terminal RP.
0 : Frequency Reference
1 : PID Feedback Value
2 : PID Setpoint
3 : Speed Feedback (V/F Control)
0
(0 - 3)
349
H6-02
(042D)
RUN
Terminal RP Frequency
Scaling
Sets the frequency of the pulse train input signal used when the item selected with H6-01
[Terminal RP Pulse Train Function] is input at 100%.
1440 Hz
(100 - 32000 Hz)
351
H6-03
(042E)
RUN
Terminal RP Function
Gain
Sets the gain used when the function in H6-01 [Terminal RP Pulse Train Function] is input
to terminal RP.
100.0%
(0.0 - 1000.0%)
351
H6-04
(042F)
RUN
Terminal RP Function
Bias
Sets the bias used when the function in H6-01 [Terminal RP Pulse Train Function] is input
to terminal RP. Sets a value at the time when the pulse train is 0 Hz.
0.0%
(-100.0 - 100.0%)
351
H6-05
(0430)
RUN
Terminal RP Filter Time
Sets the time constant for the pulse train input primary delay filters.
0.10 s
(0.00 - 2.00 s)
351
H6-06
(0431)
RUN
Terminal MP Monitor
Selection
Sets a function for pulse train monitor output terminal MP. Sets the x-xx part of the Ux-xx
monitor.
102
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851
- 855)
351
H6-07
(0432)
RUN
Terminal MP Frequency
Scaling
Sets the frequency of the pulse train output signal used when the monitor set with H6-06
[Terminal MP Monitor Selection] is 100%.
1440 Hz
(0 - 32000 Hz)
352
H6-08
(043F)
Terminal RP Minimum
Frequency
Sets the minimum frequency of the pulse train signal that terminal RP can detect.
0.5 Hz
(0.1 - 1000.0 Hz)
352
H7: Virtual MFIO selection
No.
(Hex.)
Name Description
Default
(Range)
Ref.
H7-00
(116F)
Expert
Virtual MFIO selection
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to
operate the virtual I/O function.
0 : Disabled
1 : Enabled
0
(0, 1)
353
H7-01
(1185)
Expert
Virtual Multi-Function
Input 1
Sets the function that enters the virtual input set in H7-10 [Virtual Multi-Function Output
1].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
F
(1 - 19F)
353
H7-02
(1186)
Expert
Virtual Multi-Function
Input 2
Sets the function that enters the virtual input set in H7-12 [Virtual Multi-Function Output
2].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
F
(1 - 19F)
353
H7-03
(1187)
Expert
Virtual Multi-Function
Input 3
Sets the function that enters the virtual input set in H7-14 [Virtual Multi-Function Output
3].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
F
(1 - 19F)
354
H7-04
(1188)
Expert
Virtual Multi-Function
Input 4
Sets the function that enters the virtual input set in H7-16 [Virtual Multi-Function Output
4].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
F
(1 - 19F)
354
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents