11 Appendix
11.2.2 Parameters
11-24
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Pn50C
Input Signal Selection 3 0000 to FFFF 8888 After restart Setup
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0 to F Same as /SPD-D
/SPD-B Signal Mapping
/SPD-D Signal Mapping (See the internal set speed control function.)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 to F Same as /SPD-D
/SPD-A Signal Mapping
0 to F Same as /SPD-D
/C-SEL Signal Mapping (Control mode change when ON (L-level))
Active on the falling edge of CN1-40 input signal.
Active on the falling edge of CN1-41 input signal.
Active on the falling edge of CN1-42 input signal.
Active on the falling edge of CN1-43 input signal.
Active on the falling edge of CN1-44 input signal.
Active on the falling edge of CN1-45 input signal.
Active on the falling edge of CN1-46 input signal.
Reserved (Do not change.)
Sets signal OFF.
Active on the rising edge of CN1-40 input signal.
Active on the rising edge of CN1-41 input signal.
Active on the rising edge of CN1-42 input signal.
Active on the rising edge of CN1-43 input signal.
Active on the rising edge of CN1-44 input signal.
Active on the rising edge of CN1-45 input signal.
Active on the rising edge of CN1-46 input signal.
(Refer to 5.6.1)
(Refer to 5.6.1)
(Refer to 5.6.1)
(Refer to 5.7.1)