EasyManuals Logo

YASKAWA Varispeed G7 User Manual

YASKAWA Varispeed G7
499 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #193 background imageLoading...
Page #193 background image
5-80
U1-13
Cumulative
operation
time
Monitors the total operating
time of the Inverter.
The initial value and the oper-
ating time/power ON time
selection can be set in o2-07
and o2-08.
(Cannot be output.)
1
hr
AAAAA4CH
Elapsed
Time
U1-14
Software
No. (flash
memory)
(Manufacturer’s ID number) (Cannot be output.) - A A A A A 4DH
FLASH ID
U1-15
Terminal
A1 input
voltage
Monitors the input voltage of
the voltage frequency refer-
ence. An input of 10 V corre-
sponds to 100%.
10 V: 100% (10 V)
(-10 to 10 V possible)
0.1
%
AAAAA4EH
Term A1
Level
U1-16
Terminal
A2 input
current
(voltage)
Monitors the input current of
the multi-function analog
input.
An input of 20 mA corre-
sponds to 100%.
20 mA: 100% (4 to 20 mA)
(0 to 10 V, -10 to 10 V possi-
ble)
0.1
%
AAAAA4FH
Term A2
Level
U1-17
Terminal
A3 input
voltage
Monitors the input voltage of
the multi-function analog
input.
An input of 10 V corresponds
to 100%.
10 V: 100% (10 V)
(-10 to 10 V possible)
0.1
%
A A A A A 050H
Term A3
Level
U1-18
Motor sec-
ondary cur-
rent (Iq)
Monitors the calculated value
of the motor secondary cur-
rent.
The motor rated secondary
current corresponds to 100%.
10 V: Motor rated
secondary current)
(-10 to 10 V output)
0.1
%
AAAAA51H
Mot SEC
Current
U1-19
Motor
exciting
current (Id)
Monitors the calculated value
of the motor excitation cur-
rent.
The motor rated secondary
current corresponds to 100%.
10 V: Motor rated
secondary current)
(-10 to 10 V output)
0.1
%
No No A A A 52H
Mot EXC
Current
U1-20
Output fre-
quency
after soft-
start
Monitors the output frequency
after a soft start.
The frequency given does not
include compensations, such
as slip compensation.
The unit is set in o1-03.
10 V: Max. frequency
(-10 to 10 V possible)
0.01
Hz
AAAAA53H
SFS Output
U1-21
ASR input Monitors the input to the speed
control loop.
The maximum frequency cor-
responds to 100%.
10 V: Max. frequency
(-10 to 10 V possible)
0.01
%
No A No A A 54H
ASR Input
U1-22
ASR output Monitors the output from the
speed control loop.
The motor rated secondary
current corresponds to 100%.
10 V: Motor rated
secondary current)
(-10 to 10 V possible)
0.01
%
No A No A A 55H
ASR Out-
put
Con-
stant
Number
Name
Description
Output Signal Level
During Multi-Function
Analog Output
Min.
Unit
Control Methods
MEMO-
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2

Table of Contents

Other manuals for YASKAWA Varispeed G7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 and is the answer not in the manual?

YASKAWA Varispeed G7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7
CategoryInverter
LanguageEnglish

Related product manuals