EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 44

YOKOGAWA DLM2000 Series
340 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-11
IM 710105-17E
Commands
1
2
3
4
5
6
App
Index
5.1 List of Commands
Command Function Page
:FILE:SAVE:{ASCii|BINary}:LENG
th
Sets or queries the number of data points to save when compressing or
sampling (decimating) various types of data.
5-102
:FILE:SAVE:{ASCii|BINary}:RANGe
Sets or queries the save range for a specific type of data. 5-102
:FILE:SAVE:{ASCii|BINary}:TRACe
Sets or queries the waveforms to save for a specific type of data. 5-102
:FILE:SAVE:ASCii:TINFormation
(Time Information)
Sets or queries whether waveform data is saved with time information (ON)
or without it (OFF).
5-103
:FILE:SAVE:FFT:FINFormation
(Frequency Information)
Sets or queries whether FFT data is saved with frequency information (ON)
or without it (OFF).
5-103
:FILE:SAVE:COMMent
Sets or queries the comment that will be attached to the data that will be
saved.
5-103
:FILE:SAVE:NAME
Sets or queries the file name for the data that will be saved. 5-103
:FILE:SAVE:SBUS:COMPression
Sets or queries the save compression method of SENT data. 5-103
:FILE:SAVE:SBUS:HISTory
Sets or queries the history for which serial bus data will be saved. 5-103
:FILE:SAVE:SBUS:LENGth
Sets or queries the number of data points to save when compressing or
sampling (decimating) SENT data.
5-103
:FILE:SAVE:SBUS:TINFormation
(Time Information)
Sets or queries whether SENT waveform data is saved with time information
(ON) or without it (OFF).
5-103
:FILE:SAVE:SBUS:TYPe
Sets or queries the save method of SENT data. 5-103
GONogo Group
:GONogo?
Queries all GO/NO-GO determination settings. 5-104
:GONogo:ABORt
Aborts GO/NO-GO determination. 5-104
:GONogo:ACTion?
Queries all of the settings related to the action executed when GO/NO-GO
results are NO-GO and the reference.
5-104
:GONogo:ACTion:BUZZer
Sets or queries whether or not the DLM2000 will sound an alarm when a
GO/NO-GO result is NO-GO.
5-104
:GONogo:ACTion:HCOPy
Sets or queries whether or not the DLM2000 will print screen images to the
optional built-in printer or an external printer for NO-GO results.
5-104
:GONogo:ACTion:MAIL?
Queries all of the settings related to email notification for NO-GO results. 5-104
:GONogo:ACTion:MAIL:COUNt
Sets or queries the upper limit of emails that will be sent for NO-GO results. 5-104
:GONogo:ACTion:MAIL:MODE
Sets or queries whether or not the DLM2000 will send email notification for
NO-GO results.
5-104
:GONogo:ACTion:SAVE
Sets or queries whether or not the DLM2000 will save waveform data to the
storage medium for NO-GO results.
5-104
:GONogo:COUNt?
Queries the number of performed GO/NO-GO determinations. 5-104
:GONogo:EXECute
Executes GO/NO-GO determination. This is an overlap command. 5-104
:GONogo:LOGic
Sets or queries the GO/NO-GO determination logic. 5-104
:GONogo:NGCount?
Queries the GO/NO-GO determination NO-GO count. 5-104
:GONogo:NGStopcount
Sets or queries the number of NO-GO results at which the DLM2000 will
stop performing determinations.
5-105
:GONogo:STOPcount
Sets or queries the number of acquisitions at which the DLM2000 will stop
performing determinations.
5-105
:GONogo:WAIT?
Waits for the completion of GO/NO-GO determination by using a timeout
timer.
5-105
:GONogo[:ZPARameter]?
Queries all zone and parameter determination settings. 5-105
:GONogo[:ZPARameter]:NUMBer<x>?
Queries all of the settings related to the specified reference standard for
zone or parameter determination.
5-105
:GONogo[:ZPARameter]:NUMBer<x>:
CAUSe?
Queries whether or not the specified waveform parameter is the cause of a
NO-GO zone or parameter determination.
5-105
:GONogo[:ZPARameter]:NUMBer<x>:
CONDition
Sets or queries the specified waveform parameter’s reference condition for
zone or parameter determination.
5-105
:GONogo[:ZPARameter]:NUMBer<x>:
MODE
Sets or queries the specified reference standard mode. 5-105
:GONogo[:ZPARameter]:NUMBer<x>:
PARameter?
Queries all parameter settings for the specified reference standard. 5-105
:GONogo[:ZPARameter]:NUMBer<x>:
PARameter:ITEM
Sets or queries the specified waveform parameter’s item for parameter
determination.
5-106
:GONogo[:ZPARameter]:NUMBer<x>:
PARameter:LIMit
Sets or queries the specified waveform parameter’s upper and lower limits
for parameter determination.
5-106
:GONogo[:ZPARameter]:NUMBer<x>:
PARameter:TRACe
Sets or queries the specified waveform parameter’s source waveform for
parameter determination.
5-106
:GONogo[:ZPARameter]:NUMBer<x>:
PARameter:VALue?
Queries the specified waveform parameter’s measured value for parameter
determination.
5-106

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Related product manuals