5-52
IM 710105-17E
Command Function Page
:WAVeform:SRATe? (Sample RATE)
Queries the sample rate of the record specified by the
:WAVeform:RECord
command.
5-281
:WAVeform:STARt
Sets or queries which point will be used as the first data value for the
waveform specified by
:WAVeform:TRACe
.
5-281
:WAVeform:TRACe
Sets or queries the waveform that WAVeform commands will be applied to. 5-281
:WAVeform:TRIGger?
Queries the trigger position of the record specified by the
:WAVeform:RECord
command.
5-281
:WAVeform:TYPE?
Queries the acquisition mode of the waveform specified by the
:WAVeform:TRACe
command.
5-281
WPARameter Group
:WPARameter<x>?
Queries all of the settings for the waveform parameter measurement feature. 5-282
:WPARameter<x>:DISPlay
Sets or queries the on/off status of waveform parameter measurement
display.
5-282
:WPARameter<x>:HISTogram?
Queries all histogram display settings for waveform parameter measurement. 5-282
:WPARameter<x>:HISTogram:MEASu
re?
Queries all automatic measurement settings of the histogram display for
waveform parameter measurement.
5-282
:WPARameter<x>:HISTogram:MEASur
e:MODE
Sets or queries the automatic measurement mode of the histogram display
for waveform parameter measurement.
5-282
:WPARameter<x>:HISTogram:MEASur
e:PARameter?
Queries all automatic measurement settings of the histogram parameter for
waveform parameter measurement.
5-282
:WPARameter<x>:HISTogram:MEASur
e:PARameter:ALL
Collectively turns on or off all histogram parameters for waveform parameter
measurement.
5-282
:WPARameter<x>:HISTogram:MEASur
e:PARameter:<Parameter>?
Queries all of the settings of a histogram parameter for waveform parameter
measurement.
5-282
:WPARameter<x>:HISTogram:MEASur
e:PARameter:<Parameter>:STATe
Sets or queries the on/off status of a histogram parameter for waveform
parameter measurement.
5-283
:WPARameter<x>:HISTogram:MEASur
e:PARameter:<Parameter>:VALue?
Queries the measured value of a histogram parameter for waveform
parameter measurement.
5-283
:WPARameter<x>:HISTogram:MEASur
e:PARameter:POSition<y>
Sets or queries the position of a histogram parameter for waveform
parameter measurement.
5-283
:WPARameter<x>:ITEM
Sets or queries a waveform parameter for waveform parameter
measurement.
5-283
:WPARameter<x>:MODE
Sets or queries the waveform parameter measurement mode. 5-283
:WPARameter<x>:TRENd?
Queries all trend display settings for waveform parameter measurement. 5-283
:WPARameter<x>:TRENd:ASCale
Executes auto scaling of the trend display for waveform parameter
measurement.
5-283
:WPARameter<x>:TRENd:CURSor?
Queries all cursor measurement settings of the trend display for waveform
parameter measurement.
5-284
:WPARameter<x>:TRENd:CURSor:C
<y>?
Queries the measured value of a cursor in the trend display for waveform
parameter measurement.
5-284
:WPARameter<x>:TRENd:CURSor:DC?
Queries the measured value between cursors in the trend display for
waveform parameter measurement.
5-284
:WPARameter<x>:TRENd:CURSor:MO
DE
Sets or queries the automatic measurement mode of the trend display for
waveform parameter measurement.
5-284
:WPARameter<x>:TRENd:CURSor:POS
ition<y>
Sets or queries the position of a cursor in the trend display for waveform
parameter measurement.
5-284
:WPARameter<x>:TRENd:HRANge
Sets or queries the trend display source window for waveform parameter
measurement.
5-284
:WPARameter<x>:TRENd:HSPan
Sets or queries the horizontal span of the trend display for waveform
parameter measurement.
5-284
:WPARameter<x>:TRENd:VERTical
Sets or queries the vertical range of the trend display for waveform
parameter measurement.
5-284
:WPARameter<x>:VTDisplay
Sets or queries the on/off status of VT waveform display. 5-285
:WPARameter<x>:WAIT?
Waits for the completion of automated measurement with a set timeout. 5-285
5.1 List of Commands