2-66
IM 04L51B01-01EN
AcknowledgingIndividualAlarms(Releasenumber2andlater)
Active alarms are acknowledged separately by channel and level.
Even when Individual alarm ACK is specified, it is possible to acknowledge all alarms at
once.
The individual alarm ACK function must be enabled. See page 1-205 in section 1.23.3,
“Setting the Alarm Display Hold/Nonhold and Individual Alarm ACK Operation”.
You can carry out this procedure after an alarm occurs.
1
Tap the digital display area of a channel.
The channel information appears.
2
Tap the Alarm ACK icon.
The individual alarm ACK selection screen appears.
Select the level.
3
Select the level to acknowledge, and tap OK.
The alarm output is released.
Operation complete
Individual alarm ACK can be executed from the following screens.
Trend
Digital
Bar graph
Overview
Custom display
2.4.2 DisablingandEnablingOperation(Operationlockfunction)
See page 2-83 in section 2.9, “Disabling Operation (Operation lock function)”.
2.4.3 ResettingTimers(Relativetimers)
Procedure
1
Press MENU.
The menu screen appears.
2
Tap the Universal tab and then Timer reset.
The reset selection screen (timer number or all) appears.
3
Select the timer to reset, and tap OK.
The timer is reset.
Operation complete
2.4 Executing Various Functions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GX20 and is the answer not in the manual?

YOKOGAWA GX20 Specifications

General IconGeneral
BrandYOKOGAWA
ModelGX20
CategoryRecording Equipment
LanguageEnglish

Related product manuals