4-60
IM 04L51B01-01EN
Data Hold
Register
Supplementary Information Data Type
Batch text field title (multi
batch support)
409451 1 or greater: Batch group
number
When reading, the batch
group number that performed
writing previously
Default value: 0
16-bit signed integer
409452 Batch text
Text field number
When reading, the batch text
field number that performed
writing previously
Default value: 0
409453 Batch Text field
Title
UTF-8 characters (2
characters)
Up to 20 characters [attach
the terminator '\0' at the end]
When reading, the batch field
title text corresponding to the
above batch group number
and batch text field number
NULL character if there is no
corresponding batch group
number or batch text field
number
| |
409478 Batch Text field
Title
UTF-8 characters (2
characters)
Up to 20 characters [attach
the terminator '\0' at the end]
When reading, the batch field
title text corresponding to the
above batch group number
and batch text field number
NULL character if there is no
corresponding batch group
number or batch text field
number
Continued on next page