EasyManua.ls Logo

YOKOGAWA GX20

YOKOGAWA GX20
707 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation
GS 04L51B01-01EN
June. 14, 2017-00
• Timesetting:Usingtouchoperation,
communicationcommand,eventactionfunction,
orSNTPclientfunction
• Timeadjustmentmethod:
Limitinwhichthetimeisgraduallyadjusted:
Selectfromtheavailablesettingsbetween5s
and 15 s.
Whethertochangeanout-of-limitoperation
immediately or report it as an error can be
selected.
Whilememorysampling:Correctsthetimeby1
msforeachsecond.
Whilememoryisstopped:Immediatelychange
the time.
• DST:Thedate/timeforswitchingbetween
standardtimeandDSTcanbespecied.
• Timezone:SetsthetimedifferencefromGMT.
• Dateformat:Select"YYYY/MM/DD","MM/DD/
YYYY","DD/MM/YYYY"or"DD.MM.YYYY".
MMexpressioncanbeselectedfromthe
numericcharacterorellipsis.Ex.January:01or
Jan
Thedelimitercanbeselectedfrom"/",".","-".
EthernetCommunicationFunctions
• Electricalspecications:ConformstoIEEE802.3
• Connection:Ethernet(10BASE-T/100BASE-TX)
• Max.segmentlength:100m
• Max.connectingconguration:CascadeMax.4
level(10BASE-T),Max.2level(100BASE-TX)
• Connector:RJ-45
• Protocols:TCP,UDP,IP,ICMP,ARP,DHCP,
HTTP, FTP, SMTP, SNTP, Modbus, and
dedicated protocols
• E-mailclient:Automaticallysende-mailat
speciedtimes.
E-mail is sent by events as below.
- Alarmoccurring/alarmcanceling(Max.50ch)
- Recoverfrompowerfailure
- Report data generating
- Storagemediumerror,FTPclientfunction
error
- Speciedtimeperiod
POPbeforeSMTPandSMTPauthentication
(PLAINandCRAM-MD5)isavailable.
• FTPclient:Automaticallytransferdatalestothe
FTP server.
Applicableles:Displaydata,eventdata,screen
image data, report data, etc.
• FTPServer:Transferles,deleteles,
manipulatedirectories,andoutputlelistsofthe
GX.
Numberofthesimultaneousconnection:Max.4
• Webserver:Webapplication,GXreal-time
monitoring and setting changes/operations can
beperformedwiththeWebbrowser.
The screen layout can be determined
independentlyofthescreenoftheGXmainunit.
Numberofthesimultaneousconnection:Max.4
• SNTPclient:InquiresthetimetotheSNTP
server and sets the GX.
• SNTPserver:OutputstheGXtime.
Time resolution: 5 ms
• DHCPclient:Automaticallyobtainthenetwork
addresssettingsfromtheDHCPserver.
• Modbusclient*:Readsdatafromanotherdevice
and writes to the registers.
Numberofconnectablesever;
GX10,GX20-1:Max.16
GX20-2:Max.32
*: Required /MC option
• Modbusserver:Loadsmeasurementandmath
channel data
Loads and writes communication channel data
Some control commands such as memory start
Modbus client* register access limitations
*: Required /MC option
Numberofthesimultaneousconnection:Max.4
• Setting/Measurementserver:Operate,set,and
outputdataoftheGXusingadedicatedprotocol.
Numberofthesimultaneousconnection:Max.4
• DARWINcompatiblecommunicationserver:
SupportssomeDARWINcommands
Communication with GX is possible using
DARWINcommunicationcommands.
• Output-relatedcommands:Output
measurement(IO)channeldata,Output
calculationchanneldata,Outputrelaystatus,
Outputthepositionofthedecimalpointforthe
measurement(IO)channel,Outputtheposition
ofthedecimalpointforthecalculationchannel,
Outputtheinformationonsystemconguration
• Setup-relatedcommands:Range,Scaleunit,
Alarm, Time, Moving average, zone
• Operation-relatedcommands:Resetalarm,
Reset timer, Start MATH calculation, Rebuild
system,Initialize,Inputcommunication,Output
communicationDO,Writemessage
BatchFunction
•
Function:Datamanagementusingbatchnames.
Entertexteldsandbatchcommentsinthedatale.
• Batchname:Addedtothelenameofthe
display data and event data.
Structure:Batchnumber(upto32characters)+
lot number (up to 8 digits)
Use/notuseselectableforlotnumber,on/off
selectableforautoincrementfunction.
• Texteld:Addstexttothedisplaydataandevent
data.
Thereare24availabletextelds.
Upto20titlecharactersand30othercharacters
canbeenteredpereld.
• Batchcomment:Addstexttothedisplaydata
and event data.
3comments(max.50characters)areavailable.
PrinterOutputFunction
• SnapshotDatacanbeprintedoutwithany
LAN-connected printer supporting the HP PCL5c
language and the port 9100.

Table of Contents

Related product manuals