EasyManua.ls Logo

YOKOGAWA GX20

YOKOGAWA GX20
707 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
All Rights Reserved. Copyright © 2014, Yokogawa Electric Corporation
GS 04L53B01-01EN May. 19, 2017-00
*1 Installationcategory(overvoltagecategory)II:
Describesanumberwhichdenesatransient
overvoltagecondition.
Impliestheregulationforimpulsewithstandvoltage.
“II”appliestoelectricalequipmentwhich
issuppliedfromthexedinstallationlikea
distribution board.
*2 Pollution degree 2:
Describesthedegreetowhichasolid,liquid,
or gas which deteriorates dielectric strength or
surfaceresistivityisadhering.
“2”appliestonormalindooratmosphere.
Normally,onlynon-conductivepollutionoccurs.
*3 TheCEstandardsformodulesrepresent
standardsthataremetwhenthemoduleis
installedinthemainunit.
*4 MeasurementcategoryII(CATII):
Appliestomeasuringcircuitsconnectedtolow
voltageinstallation,andelectricalinstruments
suppliedwithpowerfromxedequipmentsuchas
electric switchboards.
*5 Thisproductisdesignedasopenequipment
undertherelevantstandard,installitasfollows:
•TheGX10/GX20isdesignedtobeinstalledinan
instrumentationpanel.
Install it in a location where people cannot touch
theterminalscarelessly.
•TomaketheGP10/GP20complywiththe
relevantstandard,supportthepartsofthedevice
other than the front-panel control area with an
instrumentationpanelorthelike,andinstallitina
locationwherepeoplecannottouchtheterminals
carelessly or in a panel.
•InstalltheGX60/GMunitinapanelwithadoor.
•Theinstrumentationpanelorpanelusedfor
supportmustcomplywithCSA/UL/EN61010-
2-201ormustbeatleastIP1X(degreesof
protection)andatleastIK09.
• WEEEDirective:Compliant
Construction
• Frontpanel(terminal):Wateranddust-proof,
ComplieswithIEC529-IP20
• Material:Polycarbonate
• Color;
Front:Charcoalgreylight(Munsell10B3.6/0.3
equivalent)
Bezel:Smokeblue(Munsell4.1PB6.0/4.5
equivalent)
• Dimensions:45.2mm(W)x111mm(H)x133.1
mm(D)(D:includingterminalcover)
• Weight:Approx.0.3kg
Power Supply
SuppyfromGX/GP,GX60expandableI/O,GM90PS
powersupplymodule.
• Powerconsumption:
GX90XA-10-U2: 0.7 W or less
GX90XA-10-T1: 0.9 W or less
GX90XA-10-C1: 0.7 W or less
GX90XA-10-L1: 0.7 W or less
GX90XA-04-H0: 2.0 W or less
GX90XA-06-R1:0.7Worless
• Withstandvoltage
Universal,Electromagneticrelay,4-wireRTD/
resistance type;
Betweentheinputterminalsandtheinternal
circuit:3000VACforoneminute
Betweentheanaloginputchannels:1000VAC
foroneminute(excludingb-terminal)
Current(mA)inputtype;
Betweentheinputterminalsandtheinternal
circuit:1500VACforoneminute
Betweentheanaloginputchannels:1000V
ACforoneminute(excludingb-terminal)
Lowwithstandvoltagetype;
Betweentheinputterminalsandtheinternal
circuit:1500VACforoneminute
Betweentheanaloginputchannels:400VAC
foroneminute(excludingb-terminal)
High-speeduniversaltype;
Betweentheinputterminalsandtheinternal
circuit:3000VACforoneminute
Betweentheanaloginputchannels:3000V
ACforoneminute
• Insulationresistance:
Betweentheinputterminalsandtheinternal
circuit:20MΩorgreaterat500VDC
Betweentheanaloginputchannels*:20MΩor
greaterat500VDC
* Excludesthebterminaloftheuniversaltype
• Recommendedreplacementperiodof
electromagneticrelayscannertypemodules:
Electromagneticrelayscannertypemodules
makemeasurementsbyswitchingmechanical
contact relays on and off.
Toensurethatthemodulescontinuetooperate
reliablyandcorrectly,replacethem
Continuoususeatmeasurementinterval1s:1year
Continuoususeatmeasurementinterval2s:2years
Continuoususeatmeasurementinterval5s:5years
Safety and EMC Standards
• CSA:
CAN/CSA22.2 No.61010-1, installation category
II
*1
, pollution degree 2
*2
CAN/CSA-C22.2 NO. 61010-2-030
CAN/CSA-IEC 61010-2-201
*5
• UL:
UL61010-1,UL61010-2-030(CSANRTL/C)
UL61010-2-201(CSANRTL/C)
*5
• CE/EMCdirective
*3
:
EN61326-1compliance,ClassATable2
EN61000-3-2compliance
EN61000-3-3compliance
EN55011 Class A Group 1
• CE/Lowvoltagedirective
*3
:
EN61010-1, EN 61010-2-030
Installation category II
*1
Pollution degree 2
*2
MeasurementcategoryII
*3
EN61010-2-201compliance
*5
• EMCRegulatoryArrangementinAustraliaand
NewZealand(RCM):EN55011compliance,
Class A Group 1
• KCmarking:Electromagneticwaveinterference
preventionstandard,electromagneticwave
protectionstandardcompliance

Table of Contents