EasyManuals Logo

YOKOGAWA GX20 User Manual

YOKOGAWA GX20
707 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #685 background imageLoading...
Page #685 background image
21
All Rights Reserved. Copyright © 2014, Yokogawa Electric Corporation
GS 04L53B01-01EN
21
May. 19, 2017-00
Subject to change without notice.
PULSE INPUT MODULE
(Model GX90XP)
GX90XP
•
Application:Pulseinput(owsumandthelike)
• Numberofinputs:10
• Measurementinterval:100ms(shortest)
• Inputtype:Contact(opencollector,voltage-free
contact),level(5Vlogic)
• Inputformat:Pulleduptoapprox.5Vthrough5
kΩ,commonpotentialsharedwithinthesame
module
• Inputrange:Upto20kHz*
*30Hzwhenthechatteringlterisinuse(On)
• Minimumdetectionpulsewidth:25μs*
*15mswhenthechatteringlterisinuse(On)
• Measurementaccuracy:Count±1pulse
Forintegrationcomputation*,thefollowing
accuracies are added.
Computationstart:+1scaninterval
Computationstop:−1scaninterval
*Integrationrequiresthemathfunction(/MToption).
• Chatteringlter:Removeschatteringupto5ms
(canbeturnedon/offoneachchannel)
*Whenthechatteringlterisoff,connectGX/GP/GMso
that it is not affected by the noise.
• Inputthresholdlevel:
Contact(opencollector,voltage-freecontact):
Countedwhenachangefrom100kΩor
higherto200Ωorlowerisdetected
Level(5Vlogic):
Countedwhenachangefrom1Vorlower
to3Vorhigherisdetected
• Hysteresiswidth:Approx.0.2V
• Contact,transistorrating:
Contact:15VDCorhigherand30mAor
higherrating.Minimumapplicableload
current1mAorless.
Transistor:Withthefollowingratings:Vce>
15VDC,Ic>30mA
• Allowableinputvoltage:±10VDC
• Insulationtype:Photocouplerisolation,
transformerisolation
• Terminaltype:M3screwterminalorclamp
terminal
• Withstandvoltage:
Betweentheinputterminalsandtheinternal
circuit:1500VACfor1minute
• Insulationresistance:
Betweentheinputterminalsandtheinternal
circuit:20MΩorgreaterat500VDC
Safety and EMC Standards
• CSA:
CAN/CSA22.2 No.61010-1, installation category
II
*1
, pollution degree 2
*2
CAN/CSA-C22.2 NO. 61010-2-030
CAN/CSA-IEC 61010-2-201
*5
• UL:
UL61010-1,UL61010-2-030(CSANRTL/C)
UL61010-2-201
*5
• CE/EMCdirective
*3
:
EN61326-1compliance,ClassATable2
EN61000-3-2compliance
EN61000-3-3compliance
EN55011 Class A Group 1
• CE/Lowvoltagedirective
*3
:
EN61010-1, EN 61010-2-030
Installation category II
*1
Pollution degree 2
*2
MeasurementcategoryII
*3
Notincludedinthemeasurementcategory
EN61010-2-201compliance
*5
• EMCRegulatoryArrangementinAustraliaand
NewZealand(RCM):EN55011compliance,
Class A Group 1
• KCmarking:Electromagneticwaveinterference
preventionstandard,electromagneticwave
protectionstandardcompliance
*1 Installationcategory(overvoltagecategory)II:
Describesanumberwhichdenesatransient
overvoltagecondition.
Impliestheregulationforimpulsewithstandvoltage.
“II”appliestoelectricalequipmentwhich
issuppliedfromthexedinstallationlikea
distribution board.
*2 Pollution degree 2:
Describesthedegreetowhichasolid,liquid,
or gas which deteriorates dielectric strength or
surfaceresistivityisadhering.
“2”appliestonormalindooratmosphere.
Normally,onlynon-conductivepollutionoccurs.
*3 TheCEstandardsformodulesrepresent
standardsthataremetwhenthemoduleis
installedinthemainunit.
*4 MeasurementcategoryII(CATII):
Appliestomeasuringcircuitsconnectedtolow
voltageinstallation,andelectricalinstruments
suppliedwithpowerfromxedequipmentsuchas
electric switchboards.
*5 Thisproductisdesignedasopenequipment
undertherelevantstandard,installitasfollows:
•TheGX10/GX20isdesignedtobeinstalledinan
instrumentationpanel.
Install it in a location where people cannot touch
theterminalscarelessly.
•TomaketheGP10/GP20complywiththe
relevantstandard,supportthepartsofthedevice
other than the front-panel control area with an
instrumentationpanelorthelike,andinstallitina
locationwherepeoplecannottouchtheterminals
carelessly or in a panel.
•InstalltheGX60/GMunitinapanelwithadoor.
•Theinstrumentationpanelorpanelusedfor
supportmustcomplywithCSA/UL/EN61010-
2-201ormustbeatleastIP1X(degreesof
protection)andatleastIK09.
• WEEEDirective:Compliant

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GX20 and is the answer not in the manual?

YOKOGAWA GX20 Specifications

General IconGeneral
BrandYOKOGAWA
ModelGX20
CategoryRecording Equipment
LanguageEnglish

Related product manuals