Q511: System low battery reports to CS
Congures the system to transmit low battery reports about the 2GIG EDGE Panel to the Central Station.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
Q512: System low battery restore reports to CS
Congures the system to transmit a report to the Central Station after a low battery condition on the 2GIG EDGE Panel is restored.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
Q513: RF low battery reports to CS
Congures the system to transmit low battery reports about the system’s sensors and peripherals to the Central Station.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
Q514: Sensor low battery restore reports to CS
Congures the system to transmit a report to the Central Station after a low battery condition for a sensor is restored.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
Q515: System disarmed reports to CS
Congures the system to transmit a report to the Central Station when the system is disarmed by a user. The report includes the keyfob or user
code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
NOTE: Arming setting on Alarm.com monitoring settings supersedes Q515: System disarmed reports to CS
Q516: System armed reports to CS
Congures the system to transmit a report to the Central Station when the system is disarmed by a user. The report includes the keyfob or user
code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
NOTE: Arming setting on Alarm.com monitoring settings supersedes Q516: System armed reports to CS
Q517: Alarm restore reports to CS
Congures the system to transmit reports to the Central Station after an alarm, either when the Bell Cutoff Time expires or when the system is
disarmed.
You have these options:
»
Enabled: The system transmits a report to the Central Station. Depending on the number of trips set for a cross sensor zone, the
feature works as follows:
»
If enabled and Q208 on page 1 is set to two (2) trips, the system transmits a report when the triggering sensor is closed (i.e., in its
normal state) at the Bell Cutoff Time or if the sensor is closed after the Bell Cutoff Time.
»
If enabled and Q208 on page 1 is set to one (1) trip, the system transmits a report only if the sensor is closed at the time the system is
disarmed. Reports are not sent if a sensor is in swinger shutdown until the time of disarm and the sensor is closed.
»
Disabled: The system does not transmit a report to the Central Station.
NOTE: Alarms setting on Alarm.com monitoring settings supersedes Q517: Alarm restore reports to CS.

Table of Contents

Other manuals for 2gig Technologies EDGE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies EDGE and is the answer not in the manual?

2gig Technologies EDGE Specifications

General IconGeneral
Brand2gig Technologies
ModelEDGE
CategorySecurity System
LanguageEnglish

Related product manuals