63
Question
Number
Question Text Available Settings
Factory Default
Setting
Programming Category Page Reference
Q119
Alert on disarm with keyfob after
alarm
Enabled
Disabled
Disabled System Conguration 45
Q120 Keyfob arm/disarm conrmation
Enabled
Disabled
Disabled System Conguration 46
Q121
Keyfob/remote arming mode on
system not ready
Auto-Bypass with Zone Participation
on Restore
Auto-Bypass
Arm Only When System Ready
Auto-Bypass with
Zone Participation
on Restore
System Conguration 46
Q122 Alarm cancel display
Enabled
Disabled
Enabled System Conguration 46
Q123 Cross sensor zones 99-100
Enabled
Disabled
Disabled System Conguration 46
Q124 Event log
Disabled
All Events Except Open/Close/Bypass
All Events Except Open/Close
All Events
All Events System Conguration 46
Q125 LED Mode Control
Enabled
Disabled
Disabled System Conguration 46
Q126 Commercial Burglary Support
Enabled
Disabled
Disabled System Conguration 46
Q201 Exit delay, in seconds (45-120) 45-120 Seconds ‡60 Seconds Timers, Delays & Counts 47
Q202 Entry delay 1, in seconds (30-240) 30-240 Seconds ‡30 Seconds Timers, Delays & Counts 47
Q203 Entry delay 2, in seconds (30-240) 30-240 Seconds ‡45 Seconds Timers, Delays & Counts 47
Q204
Alarm cancel time, in minutes
(5-255)
5-255 Minutes 5 Minutes Timers, Delays & Counts 47
Q205
Alarm abort window transmission
delay
15 Seconds
30 Seconds
45 Seconds
30 Seconds Timers, Delays & Counts 47
Q206 Burglary bell cutoff time
4 Minutes
8 Minutes
12 Minutes
16 Minutes
Unlimited Time
‡4 Minutes Timers, Delays & Counts 47
Q207 Fire bell cutoff time
4 Minutes
8 Minutes
12 Minutes
16 Minutes
Unlimited Time
‡4 Minutes Timers, Delays & Counts 48
Q208 Swinger shutdown count (1-6) 1-6 Trips 2 Trips Timers, Delays & Counts 48
Q209
Cross sensor timeout, in seconds
(10-120)
10-120 Seconds 10 Seconds Timers, Delays & Counts 48
Q210 Time to detect AC loss, in minutes 0-30 Minutes 10 Minutes Timers, Delays & Counts 48
Q211 Random AC loss report time
Enabled
Disabled
Enabled Timers, Delays & Counts 48
Q212 Siren supervision time
Disabled
15 Seconds
30 Seconds
45 Seconds
Disabled Timers, Delays & Counts 49

Table of Contents

Other manuals for 2gig Technologies EDGE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies EDGE and is the answer not in the manual?

2gig Technologies EDGE Specifications

General IconGeneral
Brand2gig Technologies
ModelEDGE
CategorySecurity System
LanguageEnglish

Related product manuals