Copyright © 2022 Nortek Security & Control LLC
65
Q501
CS lack of usage notication time, in
days (0- 255)
0- 255 Days 7 Days Reporting 52
Q502 Periodic test, in days (0-255) 0-255 Days 30 Days Reporting 52
Q503 Programming mode entry reports to CS
Enabled
Disabled
Disabled Reporting 52
Q504 Trouble reports to CS
Enabled
Disabled
Enabled Reporting 53
Q505 Trouble restore reports to CS
Enabled
Disabled
Enabled Reporting 53
Q506 Manual bypass reports to CS
Enabled
Disabled
Disabled Reporting 53
Q507 Bypass restore reports to CS
Enabled
Disabled
Disabled Reporting 53
Q508 Force bypass reports
Enabled
Disabled
Disabled Reporting 53
Q509 AC loss reports to CS
Enabled
Disabled
Enabled Reporting 53
Q510 AC restore reports to CS
Enabled
Disabled
Enabled Reporting 53
Q511 System low battery reports to CS
Enabled
Disabled
Enabled Reporting 54
Q512 System low battery restore reports to CS
Enabled
Disabled
Enabled Reporting 54
Q513 RF low battery reports
Enabled
Disabled
Enabled Reporting 54
Q514 Sensor low battery restore reports to CS
Enabled
Disabled
Enabled Reporting 54
Q515 System disarmed reports to CS
Enabled
Disabled
Disabled Reporting 54
Q516 System armed reports to CS
Enabled
Disabled
Disabled Reporting 54
Q517 Alarm restore reports to CS
Enabled
Disabled
Disabled Reporting 54
Q518 Smart test reports
Enabled
Disabled
Disabled Reporting 55
Question
Number
Question Text Available Settings
Factory Default
Setting
Programming
Category
Page Reference