Operation and Maintenance
221
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
E-mail successfully sent The system has now successfully sent an e-mail.
Meaning of the parameter values in Tab. 101
Cause/action=0000, e-mail cli-
ent, additional information,
date, time
ESME reachable The LAN connection between the SMSC and
the ESME is now available
IP address, date, time
ESME unreachable The LAN connection between the SMSC and
the ESME is interrupted
IP address, date, time
Ethernet activated again The overload on the Ethernet interface no
longer exists. The interface has been reacti-
vated.
Date, time
Ethernet deactivated due to
high load
The system has detected an overload on the
Ethernet interface. The interface is temporarily
deactivated.
Date, time
External event message desti-
nation not reachable
External signal destination not automatically
reachable
Cause (0: Busy /1: Not available
/2:(not used), 2: Barred /3: not
defined), date, time
External event message desti-
nation reachable
External signal destination is now reachable Date, time
Fan failure The fan is jammed or defective or the connec-
tion is no longer making contact.
Parameter = 0: No more fans in operation.
Risk of overheating: Replace defective fan.
Parameter, date, time
Fan in operation The fan is back in service again after a failure.
Parameter = 0: Fan back in service again.
Parameter, date, time
FIAS command buffer full The command buffer to the PMS interface is
full.
Date, time
FIAS interface usable again The command buffer to the PMS interface is
back below the critical limit.
Date, time
G.729 Codecs within the
licence limit again
Free G.729 codecs are once again available for
connections.
Date, time
Inactive radio unit port Radio unit not responding
Reason: 0: Startup running, 1: Not registered,
2: Various nodes, 3: Port not permitted, 4: Local
power supply, 5: Not connected, 6: Port reset,
7: Startup error, 8: Unknown error
Card number, port number,
radio unit ID/reason, date, time
Incompatible PMS applica-
tion
The external hotel management system (PMS
application) is not suitable for communicating
with the communication server.
PMS SW version, PMS interface
version, PMS interface driver
version, date, time
Insufficient bandwidth An user in an AIN is trying to set up a connec-
tion and the bandwidth currently available
with the WAN link is insufficient.
Link ID, WAN link name, availa-
ble bandwidth in Kbit/s, date,
clock
Internal event message desti-
nation not reachable
Local output blocked or not available Cause (0: Busy /1: Not available
/2:(not used), 2: Barred /3: not
defined), date, time
Internal event message desti-
nation reachable
Local output available once again Date, time
Event / error message Trigger condition Details