9. Push the cover to lock into position.
8
9
Capacitors
The DC link of the drive contains several electrolytic capacitors. Operating time, load, and
surrounding air temperature have an effect on the life of the capacitors. Capacitor life can
be extended by decreasing the surrounding air temperature.
Capacitor failure is usually followed by damage to the unit and an input cable fuse failure,
or a fault trip. If you think that any capacitors in the drive have failed, contact ABB.
Reforming the capacitors
The capacitors must be reformed if the drive has not been powered (either in storage or
unused) for a year or more. The manufacturing date is on the type designation label. For
information on reforming the capacitors, see Converter module capacitor reforming
instructions (3BFE64059629 [English]) in the ABB Library (https://library.abb.com/en).
94 Maintenance

Table of Contents

Other manuals for ABB ACS480

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS480 and is the answer not in the manual?

ABB ACS480 Specifications

General IconGeneral
Output Voltage0 to Input Voltage
Frame SizesR1 to R4
Control MethodScalar control
CommunicationModbus RTU
Optional CommunicationPROFINET, EtherNet/IP
STOSafe torque off (STO) as standard
Built-in FeaturesEMC filter
Protection FeaturesOvervoltage, undervoltage, overcurrent, overload, short circuit, overtemperature