496 Control chain diagrams
Torque limitation
30.30 Overvoltagecontrol
Value
26.01 Torq reference to TC
Value
DC voltage
limiter
30.31 Undervoltagecontrol
Value
Power limiter Torque limiter
24.02 Used speed feedback
Value
30.26Powermotoringlimit
30.27Powergeneratinglimit
Value
Value
26.02 Torque reference used
Current limiter
Load angle
limitation
Motor pull-out
limitation
30.17 Maximum current
Value
30.02 Torque limit status
To TC
Value
30.02 Torque limit status
Bit Name
0 = Undervoltage
1 = Overvoltage
2 = Minimum torque
3 = Maximum torque
4 = Internal current
5 = Load angle
6 = Motor pull-out
7 = Reserved
8 = Thermal
9 = Max current
10 = User current
11 = Thermal IGBT
12 = IGBT overtemperature
13 = IGBT overload
14 =
15 =
30.19 Minimum torque
Value
30.21 Min torque 2 source
30.18 Torq lim sel
Value
Selection
>
30.20 Maximum torque
Value
Selection
>
30.22 Max torque 2 source

Table of Contents